Indium- Sealing With

Indium creates effective and reliable helium tight hermetic seals between metals or non-metallics like glass and ceramics. For example, indium can be used to seal non-wettable surfaces in cryogenic applications, vacuum pumps and in heat-sensitive areas.

When indium is used as the sealant, a chemical bond is formed between this silvery, semi-precious metal and the surfaces to be mated. Gaskets made from other materials only form a barrier to the medium being contained. Indium seals are far less sensitive to mechanical shock, vibration and low temperatures than other types of seals.

A characteristic of indium is that it forms an oxide film on its surface. In order to present clean indium metal to a substrate, this film must be broken by compression and plastic deformation. Only by breaking the oxide film is it possible to obtain a chemical bond between indium and another surface without the use of heat. This process is easy to accomplish since indium readily flows under pressure, even at cryogenic temperatures.

 

The Quality of an Indium Seal Depends Upon:

The purity and the cleanliness of the Indium used

            99.99% is the preferred purity although some very critical applications call for 99.999% purity. Pretreatment of the seal is not usually necessary, but heavy contamination with organic compounds should be removed by degreasing. Surface oxide can be etched off by using 50% hydrochloric acid (a 2-4 second dip) followed by rinsing in deionized water.

Surface Preparation

            All surfaces must be clean and dry. Glass and ceramic surfaces must be cleaned with a mixture of chromic and sulfuric acids, followed by hydrochloric acid and deionized water to a high polish. Drying can be done in an oven or by passing through a gas flame. In super-clean applications, cleaning is done by bombarding with ultra-violet light or with an electrical plasma. Metal surfaces can be bare, pre-tinned with indium or plated with indium or silver. Bare surfaces can be polished using very fine abrasive powders or can have a fine, machined finish. Fine machine finishes should not be "improved" using abrasive powders, cloths, etc.

Thickness and shape of Indium

            While some flat seals can be as thin as 0.008" (0.2 mm), other applications call for 0.062" (1.6mm) thick material. Indium seal thickness depends upon the area of the mating surfaces and the compressive force on the seal. If the seal is placed in an 'O' ring groove, the seal should be sized so that when it is compressed it overfills the groove by 5 - 15%. In some applications, overlapping segments of indium can perform as well as a continuous washer. Correctly formed seals have leak rates of less than 2 x 10-7 torr x liter / sec.

Home Page Content Under Periodic Table

ALLOYS

Click on the Alloy to go to the Online Catalog page.

 

Welcome to

ESPI was incorporated in 1950 with a mission to provide a competitive source for high purity metals, metal compounds and alloys. We are a valuable resource for virtually all major universities worldwide, global corporate R&D laboratories, thousands of domestic and international manufacturing companies and all U.S. government research laboratories. ESPI offers unique advantages often unavailable from larger organizations with no minimum order size & all business hour calls are handled by a competent sales representative. Automated answering systems and voice mail are not an option at ESPI.

Located within our fabrication facility is the melting department, forging & shaping areas, and the rod & wire, and sheet & foil departments providing the following manufacturing capabilities:

  • Casting of pure metals and alloys
  • Vacuum arc melting
  • Induction melting
  • Rod and wire drawing/extrusion
  • Sheet, foil and ribbon rolling
  • CNC milling and machining

Tel: 541-488-8311 - Email: sales@espimetals.com - or click the "Live Help/Chat Now" icon, upper right.

 

FORMS

ESPI produces and sells 68 elements and dozens of alloys in various forms for your custom needs. Click on the forms below to be directed to detailed information on manufacturing.

 

 

At We Keep Good Company


Aerospace and Defense
Northrop Grumman, Hewlett Packard, IBM, Lockheed-Martin, Hughes, Boeing, General Dynamics, Aerojet, Litton, General Electric


Medical Instruments & Technology
Cintron, Hologic/Lorad, Varian, Siemens Medical, St Jude Medical, ArthroCare, GE Medical, Harvard Medical School, City of Hope Medical Center, American Medical Systems, Cedars Sinai Medical Center


International
Atomic Energy of Canada, CNRS, European Synchrotron Radiation Facility, INRS, Alberta Research Council, National Research Council of Canada, UNAM, CISRO, CERN


Education
Stanford, UCLA, Harvard, Georgia Institute of Technology, Caltech, Johns Hopkins University, University of Arizonia, Penn State, University of Michigan, Princeton, Yale, University of Wollongong, University of Tokoyo, University of Toronto, Tulane, University of New South Wales, Max-Planck Institute, University of Freiburg


Government Research Labs
JPL, Los Alamos National Lab, Battelle Pacific NW National Lab, US Department of Energy, Argonne National Lab, Brookhaven National Lab, Naval Oceans Systems Center, US Air Force, Lawrence Berkeley National Lab, NASA


Green Energy
Origin Energy Solar, First Solar, Schott Solar, SunPower Corporation, Nanosolar, Inc.