Titanium Aluminum Vanadium Alloy
SAFETY DATA SHEET
1 PRODUCT AND SUPPLIER IDENTIFICATION
Product Name: Titanium Aluminum Vanadium Alloy - sheet, rod, wire
Other: Titanium 6Al-4V, Titanium 6/4, Titanium Grade 5
Supplier: ESPI Metals
1050 Benson Way
Ashland, OR 97520
Telephone: 800-638-2581
Fax: 541-488-8313
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
Emergency: Infotrac 800-535-5053 (US) or 352-323-3500 (24 hour)
Recommended Uses: Scientific Research
2 HAZARDS IDENTIFICATION
GHS Classification (29 CFR 1910.1200): Not classified as hazardous
GHS Label Elements:
Signal Word: N/A
Hazard Statements: N/A
Precautionary Statements: N/A
3 COMPOSITION/INFORMATION ON INGREDIENTS
Ingredient: CAS#: %: EC#:
Titanium 7429-32-6 88-90 231-142-3
Aluminum 7429-90-5 5.5-6.75 231-072-3
Vanadium 7440-62-2 3.5-4.5 231-171-1
Iron 7439-89-6 <1 231-096-4
4 FIRST AID MEASURES
General Measures: Under normal handling and use, exposure to solid forms of this material present few health hazards. Subsequent operations such as grinding, melting or welding may produce potentially hazardous dust or fumes which can be inhaled or come in contact with the skin or eyes.
INHALATION: Remove to fresh air, keep warm and quiet, give oxygen if breathing is difficult. Seek medical attention.
INGESTION: Rinse mouth with water. Do not induce vomiting. Seek medical attention. Never induce vomiting or give anything by mouth to an unconscious person.
SKIN: Remove contaminated clothing, brush material off skin, wash affected area with soap and water. Seek medical attention if symptoms develop or persist.
EYES: Flush eyes with lukewarm water, including under upper and lower eyelids, for at least 15 minutes. Seek medical attention if symptoms develop or persist.
Most Important Symptoms/Effects, Acute and Delayed: May cause irritation. See section 11 for more information.
Indication of Immediate Medical Attention and Special Treatment: No other relevant information available.
5 FIREFIGHTING MEASURES
Extinguishing Media: Use suitable extinguishing agent for surrounding materials and type of fire.
Unsuitable Extinguishing Media: Do not use water in fighting fires around molten metal. Do not use halogenated extinguishing agents on small chips/fines.
Specific Hazards Arising from the Material: This product does not present fire or explosion hazards as shipped. Small chips, fine turnings and dust from processing may be readily ignitable. May emit toxic metal oxide fumes under fire conditions.
Special Protective Equipment and Precautions for Firefighters: Full face, self-contained breathing apparatus and full protective clothing when necessary.
6 ACCIDENTAL RELEASE MEASURES
Personal Precautions, Protective Equipment, and Emergency Procedures: Wear appropriate respiratory and protective equipment specified in section 8. Avoid dust formation.
Methods and Materials for Containment and Cleaning Up: Sweep or scoop up. Place in appropriate waste disposal container.
Environmental Precautions: Do not allow to be released to the environment.
7 HANDLING AND STORAGE
Precautions for Safe Handling: Avoid creating dust as dusts may present a fire hazard. See section 8 for information on personal protection equipment.
Conditions for Safe Storage: Store in a cool, dry area. Store away from acids. See section 10 for more information on incompatible materials.
8 EXPOSURE CONTROLS AND PERSONAL PROTECTION
Exposure Limits: OSHA/PEL: ACGIH/TLV:
Titanium No exposure limit established No exposure limit established
Aluminum 5 mg/m3 (respirable) 1 mg/m3 (respirable)
Vanadium No exposure limit established No exposure limit established
Engineering Controls: Ensure adequate ventilation to maintain exposures below occupational limits. Whenever possible the use of local exhaust ventilation or other engineering controls is the preferred method of controlling exposure to airborne dust and fume to meet established occupational exposure limits. Use good housekeeping and sanitation practices. Do not allow dusts to accumulate as they may present a serious fire hazard. Do not use tobacco or food in work area. Wash thoroughly before eating or smoking. Do not blow dust off clothing or skin with compressed air.
Respiratory Protection: If permissible levels are exceeded, use NIOSH approved dust respirator.
Eye Protection: Safety glasses
Skin Protection: Wear impermeable gloves, protective work clothing as necessary.
9 PHYSICAL AND CHEMICAL PROPERTIES
Appearance:
Form: Solid in various forms
Color: Silver gray metallic
Odor: Odorless
Odor Threshold: Not determined
pH: N/A
Melting Point: 1600 oC - 1650 oC
Boiling Point: No data
Flash Point: N/A
Evaporation Rate: N/A
Flammability: N/A
Upper Flammable Limit: No data
Lower Flammable Limit: No data
Vapor Pressure: No data
Vapor Density: N/A
Relative Density (Specific Gravity): ~4.5 g/cc @ 20 oC
Solubility in H2O: Insoluble
Partition Coefficient (n-octanol/water): Not determined
Autoignition Temperature: No data
Decomposition Temperature: No data
Viscosity: N/A
10 STABILITY AND REACTIVITY
Reactivity: No data
Chemical Stability: Stable under recommended storage conditions.
Possibility of Hazardous Reactions: Titanium fines or dusts will burn when exposed to an ignition source.
Conditions to Avoid: Avoid creating or accumulating fines or dusts.
Incompatible Materials: Acids, oxidizing agents.
Hazardous Decomposition Products: Titanium oxide fume.
11 TOXICOLOGICAL INFORMATION
Likely Routes of Exposure: Inhalation, skin, eyes. Product as shipped does not present an inhalation hazard; however subsequent operations may create dusts or fumes which could be inhaled.
Symptoms of Exposure: May cause irritation if dusts or fumes are inhaled or swallowed. Fines/dusts may irritate skin and eyes.
Acute and Chronic Effects:
Titanium: Titanium is generally considered to be physiologically inert.
Aluminum: There is strong evidence that aluminum (compounds) can cause irritation following exposure via either inhalation or injection. Modest evidence of an effect exists for reproductive toxicity following oral exposure, for neurological toxicity following either oral or injection exposure, and for bone toxicity following injection exposure. All other effects were judged to be supported by either limited evidence or no clear evidence at all.1
Vanadium: No data
Acute Toxicity: No data
Carcinogenicity: No components of this alloy have been identified by NTP or IARC as carcinogenic.
To the best of our knowledge the chemical, physical and toxicological characteristics of the substance are not fully known.
12 ECOLOGICAL INFORMATION
Ecotoxicity: No data
Persistence and Degradability: No data
Bioaccumulative Potential: No data
Mobility in Soil: No data
Other Adverse Effects: Do not allow material to be released to the environment without proper governmental permits. No further relevant information available.
13 DISPOSAL CONSIDERATIONS
Waste Disposal Method:
Product: Dispose of in accordance with Federal, State and Local regulations.
Packaging: Dispose of in accordance with Federal, State and Local regulations.
14 TRANSPORT INFORMATION
Shipping Regulations: Not regulated
UN Number: N/A
UN Proper Shipping Name: N/A
Transport Hazard Class: N/A
Packing Group: N/A
Marine Pollutant: No
15 REGULATORY INFORMATION
TSCA Listed: All components are listed.
Regulation (EC) No 1272/2008 (CLP): N/A
Canada WHMIS Classification (CPR, SOR/88-66): N/A
HMIS Ratings: Health: 0 Flammability: 0 Physical: 0
NFPA Ratings: Health: 0 Flammability: 0 Reactivity: 0
Chemical Safety Assessment: A chemical safety assessment has not been carried out.
16 OTHER INFORMATION
1Krewski et al. (2007) Human Health Risk Assessment for Aluminum, Aluminum Oxide, and Aluminum Hydroxide, http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2782734/
The information contained in this document is based on the state of our knowledge at the time of publication and is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. ESPI Metals makes no representation, warranty, or guarantee of any kind with respect to the information contained in this document or any use of the product based on this information. ESPI Metals shall not be held liable for any damages resulting from handling or from contact with the above product. Users should satisfy themselves that they have all current data relevant to their particular use.
Prepared by: ESPI Metals
Revised/Reviewed: December 2014