ELECTRONIC SPACE PRODUCTS INTERNATIONAL
1050 Benson Way, Ashland, OR 97520
Toll Free (800) 638-2581 * Fax (541) 488-8313
E-Mail: sales@espimetals.com
MATERIAL SAFETY DATA SHEET
I PRODUCT IDENTIFICATION
Trade Name: Ammonium Hexachlororuthenate IV Formula: (NH4)2RuCl6
II HAZARDOUS INGREDIENTS
%: 100 TLV (Units): 1.0 mg/m3
III PHYSICAL DATA
Boiling Point: Decomposes Melting Point: Decomposes
Specific Gravity: N/A Solubility in Water: N/A
Appearance and Odor: Red-brown crystalline powder, odor of chlorine.
IV FIRE AND EXPLOSION HAZARDS DATA
Flash Point: N/A
Flammable Limits: Not flammable
Extinguishing Media: CO2, foam, dry chemical.
Special Firefighting Procedures: Self-contained breathing apparatus.
Unusual Fire and Explosion Hazards: May emit toxic fumes of Cl2, NOx, RuO4 on decomposition
V HEALTH HAZARD INFORMATION
Effects of Over Exposure: Decomposition products can be hazardous, skin irritation, ocular disturbances, respiratory problems.
EMERGENCY AND FIRST AID PROCEDURES:
INHALATION: Remove patient from area of exposure to fresh air.
INGESTION: Contact poison control center/physician.
SKIN: Flush with soap and water for 15 minutes.
EYES: Flush with eye bath.
VI REACTIVITY DATA
Stability: Stable
Conditions to Avoid: Extreme heat.
Incompatible Materials: Oxidizers, acids, alkalies.
Hazardous Decomposition Products: RuO4, NOx, Cl2
Hazardous Polymerization: Will not occur
VII SPILL OR LEAK PROCEDURES
Steps to be Taken in Case Material is Released or Spilled: Sweep up and place in airtight plastic container.
Waste Disposal Method: Dispose of in accordance with all Local, State, and Federal regulations.
VIII SPECIAL PROTECTION INFORMATION
Respiratory Protection: NIOSH/MSHA approved.
Ventilation: Fume hood
Protective Gloves: Rubber for all contact
Eye Protection: Goggles
Other Protective Equipment: Normal labwear.
IX SPECIAL PRECAUTIONS
Precautions to Be Taken in Storage and Handling: Store in cool dry place, keep tightly sealed when not in use, read MSDS before using.
Labeling: In compliance with OSHA and NFPA requirements.
The above information is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. ESPI shall not be held liable for any damage resulting from handling or from contact with the above product.
Issued By: Steve Dierks
Date: November 1994