ELECTRONIC SPACE PRODUCTS INTERNATIONAL


1050 Benson Way, Ashland, OR 97520

Toll Free (800) 638-2581 * Fax (541) 488-8313

E-Mail: sales@espimetals.com

 

 

MATERIAL SAFETY DATA SHEET

 

 

 

I            PRODUCT IDENTIFICATION


 

 

Trade Name:      Ammonium Hexachlororuthenate IV                                          Formula:            (NH4)2RuCl6

 

 

II           HAZARDOUS INGREDIENTS


 

 

%:         100                                                                                                             TLV (Units):      1.0 mg/m3

 

 

III         PHYSICAL DATA


 

 

Boiling Point:                   Decomposes                                                                  Melting Point:                  Decomposes

Specific Gravity:              N/A                                                                               Solubility in Water:         N/A

Appearance and Odor:    Red-brown crystalline powder, odor of chlorine.

 

 

IV         FIRE AND EXPLOSION HAZARDS DATA


 

 

Flash Point: N/A

Flammable Limits: Not flammable

 

Extinguishing Media: CO2, foam, dry chemical.

Special Firefighting Procedures: Self-contained breathing apparatus.

Unusual Fire and Explosion Hazards: May emit toxic fumes of Cl2, NOx, RuO4 on decomposition

 

 

V           HEALTH HAZARD INFORMATION


 

 

Effects of Over Exposure: Decomposition products can be hazardous, skin irritation, ocular disturbances, respiratory problems.

 

EMERGENCY AND FIRST AID PROCEDURES:

 

INHALATION: Remove patient from area of exposure to fresh air.

INGESTION: Contact poison control center/physician.

SKIN: Flush with soap and water for 15 minutes.

EYES: Flush with eye bath.

 

 

VI         REACTIVITY DATA


 

 

Stability: Stable

 

Conditions to Avoid: Extreme heat.

Incompatible Materials: Oxidizers, acids, alkalies.

 

Hazardous Decomposition Products: RuO4, NOx, Cl2

Hazardous Polymerization: Will not occur

VII        SPILL OR LEAK PROCEDURES


 

 

Steps to be Taken in Case Material is Released or Spilled: Sweep up and place in airtight plastic container.

 

Waste Disposal Method: Dispose of in accordance with all Local, State, and Federal regulations.

 

 

VIII      SPECIAL PROTECTION INFORMATION


 

 

Respiratory Protection: NIOSH/MSHA approved.

Ventilation: Fume hood

 

Protective Gloves: Rubber for all contact

Eye Protection: Goggles

 

Other Protective Equipment: Normal labwear.

 

 

IX         SPECIAL PRECAUTIONS


 

 

Precautions to Be Taken in Storage and Handling: Store in cool dry place, keep tightly sealed when not in use, read MSDS before using.

 

Labeling: In compliance with OSHA and NFPA requirements.

 

              The above information is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. ESPI shall not be held liable for any damage resulting from handling or from contact with the above product.

 

 

Issued By:           Steve Dierks

Date:                    November 1994