1 PRODUCT AND SUPPLIER IDENTIFICATION Product Name: Lanthanum Powder Formula: La Supplier: ESPI Metals 1050 Benson Way Ashland, OR 97520 Telephone: 800-638-2581 Fax: 541-488-8313 Email: This email address is being protected from spambots. You need JavaScript enabled to view it. Emergency: Infotrac 800-535-5053 (US) or 352-323-3500 (24 hour) Recommended Uses: Scientific Research
2 HAZARDS IDENTIFICATION GHS Classification (29 CFR 1910.1200): Flammable solids, category 1. GHS Label Elements: Signal Word: Danger Hazard Statements: H228 Flammable solid. Precautionary Statements: P210 Keep away from heat/sparks/open flames/hot surfaces - No smoking, P280 Wear protective gloves/protective clothing/eye protection/face protection, P370+P378 In case of fire: Use Class D dry chemical extinguishing agent for extinction.
3 COMPOSITION/INFORMATION ON INGREDIENTS Ingredient: Lanthanum CAS#: 7439-91-0 %: 100 EC#: 231-099-0
4 FIRST AID MEASURES General Measures: Remove patient from area of exposure. INHALATION: Remove to fresh air, keep warm and quiet, give oxygen if breathing is difficult. Seek medical attention. INGESTION: Quickly wipe material from mouth and rinse with water. Do not induce vomiting. Seek medical attention. SKIN: Remove contaminated clothing, brush material off skin, wash affected area with soap and water. Seek medical attention if symptoms persist. EYES: Flush eyes with lukewarm water, including under upper and lower eyelids, for at least 15 minutes. Seek medical attention if symptoms persist. Most Important Symptoms/Effects, Acute and Delayed: May cause irritation. See section 11 for more information. Indication of Immediate Medical Attention and Special Treatment: No other information available.
5 FIREFIGHTING MEASURES Extinguishing Media: Use Class D dry powder extinguishing agent. Unsuitable Extinguishing Media: Do not use water. Specific Hazards Arising from the Material: Flammable in the form of dust or powder when exposed to heat, sparks or flame. May react with water under fire conditions liberating flammable hydrogen gas. May emit fumes of lanthanum oxide under fire conditions. Special Protective Equipment and Precautions for Firefighters: Full face, self-contained breathing apparatus and full protective clothing to prevent contact with skin and eyes.
6 ACCIDENTAL RELEASE MEASURES Personal Precautions, Protective Equipment, and Emergency Procedures: Wear appropriate respiratory and protective equipment specified in section 8. Isolate spill area and provide ventilation. Avoid breathing dust or fume. Avoid contact with skin and eyes. Eliminate all sources of ignition. Methods and Materials for Containment and Cleaning Up: Avoid dust formation. Sweep or scoop spilled product and place in a closed container for further handling and disposal. Do not use water for spill clean-up. Use only non-sparking tools and natural bristle brushes. Environmental Precautions: Do not flush to sewer, stream, or other bodies of water. Do not allow to enter drains or to be released to the environment.
7 HANDLING AND STORAGE Precautions for Safe Handling: Handle under dry protective gas such as argon. Handle in an enclosed, controlled process. Use non-sparking tools. Protect from sources of ignition. Avoid creating dust. Avoid breathing dust or fumes. Provide adequate ventilation if dusts are created. Avoid contact with skin and eyes. Wash thoroughly before eating or smoking. See section 8 for information on personal protection equipment. Conditions for Safe Storage, Including Any Incompatibilities: Store in tightly-sealed containers under argon. Store in a cool, dry, well-ventilated area. Storage area should be free of combustibles and ignition sources. Protect from water/moisture. See section 10 for more information on incompatible materials.
8 EXPOSURE CONTROLS AND PERSONAL PROTECTION Exposure Limits: Lanthanum OSHA/PEL: No exposure limit established ACGIH/TLV: No exposure limit established Appropriate Engineering Controls: Handle in an enclosed, controlled process under dry argon. Use local exhaust to maintain exposure at low levels. Whenever possible the use of local exhaust ventilation or other engineering controls is the preferred method of controlling exposure to airborne dust and fume to meet established occupational exposure limits. Do not use tobacco or food in work area. Wash thoroughly before eating or smoking. Do not blow dust off clothing or skin with compressed air. Prepare for the possibility of a fire. Keep extinguishing agents, tools for handling and protective clothing readily available. Individual Protection Measures, Such as Personal Protective Equipment: Respiratory Protection: Wear a NIOSH/MSHA approved respirator when high concentrations are present. Eye Protection: Always wear approved chemical splash proof goggles. Skin Protection: Rubber gloves, flame retardant protective work clothing.
9 PHYSICAL AND CHEMICAL PROPERTIES Appearance: Form: Powder Color: Gray metallic Odor: Not determined Odor Threshold: Not determined pH: N/A Melting Point: 918 oC Boiling Point: 3464 oC Flash Point: N/A Evaporation Rate: N/A Flammability: Flammable solid Upper Flammable Limit: No data Lower Flammable Limit: No data Vapor Pressure: No data Vapor Density: N/A Relative Density (Specific Gravity): 6.17 g/cc at 20 oC Solubility in H2O: Decomposes Partition Coefficient (n-octanol/water): Not determined Autoignition Temperature: No data Decomposition Temperature: No data Viscosity: N/A
10 STABILITY AND REACTIVITY Reactivity: No data Chemical Stability: Stable under recommended storage conditions. Possibility of Hazardous Reactions: Flammable in the form of dust or powder when exposed to heat, sparks or flame. Reacts vigorously with acids releasing flammable hydrogen gas. May react with water under fire conditions liberating flammable hydrogen gas. Conditions to Avoid: Avoid contact with air, water, moisture or possible ignition sources such as sparks or flame. Incompatible Materials: Water/moisture, air, strong acids, strong oxidizing agents, acid chlorides, halogens. Hazardous Decomposition Products: Lanthanum oxides, lanthanum hydroxides, hydrogen gas.
11 TOXICOLOGICAL INFORMATION Likely Routes of Exposure: Inhalation, skin and eyes. Symptoms of Exposure: May cause irritation. Acute and Chronic Effects: No data Acute Toxicity: No data Carcinogenicity: NTP: Not identified as carcinogenic IARC: Not identified as carcinogenic To the best of our knowledge the chemical, physical and toxicological characteristics of the substance are not fully known.
12 ECOLOGICAL INFORMATION Ecotoxicity: No data Persistence and Degradability: No data Bioaccumulative Potential: No data Mobility in Soil: No data Other Adverse Effects: Do not allow material to be released to the environment. No further relevant information available.
13 DISPOSAL CONSIDERATIONS Waste Disposal Method: Product: Dispose of in accordance with Federal, State and Local regulations. Packaging: Dispose of in accordance with Federal, State and Local regulations.
14 TRANSPORT INFORMATION UN Number: UN3089 UN Proper Shipping Name: Metal powder, flammable, n.o.s., (Lanthanum) Transport Hazard Class: 4.1 Packing Group: II Marine Pollutant: No
15 REGULATORY INFORMATION TSCA Listed: All components are listed. Regulation (EC) No 1272/2008 (CLP): Flammable solids, category 1. Canada WHMIS Classification (CPR, SOR/88-66): Flammable solids. HMIS Ratings: Health: 1 Flammability: 3 Physical: 1 NFPA Ratings: Health: 1 Flammability: 3 Instability: 1 Chemical Safety Assessment: A chemical safety assessment has not been carried out.
16 OTHER INFORMATION The information contained in this document is based on the state of our knowledge at the time of publication and is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. ESPI Metals makes no representation, warranty, or guarantee of any kind with respect to the information contained in this document or any use of the product based on this information. ESPI Metals shall not be held liable for any damages resulting from handling or from contact with the above product. Users should satisfy themselves that they have all current data relevant to their particular use.
Prepared by: ESPI Metals Revised/Reviewed: July 2015
|