Tungsten Rhenium Alloy

 

 

SAFETY DATA SHEET

 

 

 

1   PRODUCT AND SUPPLIER IDENTIFICATION

 

Product Name:    Tungsten-Rhenium Alloy - wire

Other:                  Tungsten-Re

 

Supplier:             ESPI Metals

                            1050 Benson Way

                            Ashland, OR 97520

Telephone:          800-638-2581

Fax:                     541-488-8313

Email:                  This email address is being protected from spambots. You need JavaScript enabled to view it.

Emergency:         Infotrac 800-535-5053 (US) or 352-323-3500 (24 hour)

Recommended Uses:   Scientific Research

 

 

2   HAZARDS IDENTIFICATION 

 

GHS Classification (29 CFR 1910.1200):   Not classified as hazardous

GHS Label Elements:

Signal Word: N/A

Hazard Statements: N/A

Precautionary Statements:   N/A

 

 

3   COMPOSITION/INFORMATION ON INGREDIENTS

Ingredient:       CAS#:                 %:               EC#:

Tungsten            7440-33-7         75-98.5          231-143-9

Rhenium            7440-15-5         1.5-25            231-124-5

 

 

4   FIRST AID MEASURES

General Measures: Under normal handling and use, exposure to solid forms of this material present few health hazards. Subsequent operations such as grinding, melting or welding may produce potentially hazardous dust or fumes which can be inhaled or come in contact with the skin or eyes.

INHALATION: Remove to fresh air, keep warm and quiet, give oxygen if breathing is difficult. Seek medical attention.

INGESTION: Rinse mouth with water. Do not induce vomiting. Seek medical attention. Never induce vomiting or give anything by mouth to an unconscious person.

SKIN: Remove contaminated clothing, brush material off skin, wash affected area with soap and water. Seek medical attention if symptoms persist.

EYES: Flush eyes with lukewarm water, including under upper and lower eyelids, for at least 15 minutes. Seek medical attention if symptoms persist.

 

Most Important Symptoms/Effects, Acute and Delayed: May cause irritation. See section 11 for more information.

Indication of Immediate Medical Attention and Special Treatment: No other relevant information available.

 

 

5   FIREFIGHTING MEASURES

Extinguishing Media: Use suitable extinguishing media for surrounding material and type of fire.

Unsuitable Extinguishing Media: No information available.

 

Specific Hazards Arising from the Material: May emit metal oxide fumes under fire conditions.

Special Protective Equipment and Precautions for Firefighters: Full face, self-contained breathing apparatus and full protective clothing when necessary.

 

 

6   ACCIDENTAL RELEASE MEASURES

Personal Precautions, Protective Equipment, and Emergency Procedures: Wear appropriate respiratory and protective equipment specified in section 8. Avoid dust formation. Avoid contact with skin and eyes. Avoid breathing dust or fume.

Methods and Materials for Containment and Cleaning Up: Sweep or scoop up. Place in a closed container for further handling and disposal.

Environmental Precautions: Do not allow to enter drains or to be released to the environment.

 

 

7   HANDLING AND STORAGE

Precautions for Safe Handling: Avoid breathing dust or fumes. Provide adequate ventilation if dusts or fumes are created. See section 8 for information on personal protection equipment.

Conditions for Safe Storage: Store in a sealed container. Store in a cool, dry area. See section 10 for more information on incompatible materials.

 

 

8   EXPOSURE CONTROLS AND PERSONAL PROTECTION

Exposure Limits:   OSHA/PEL:                            ACGIH/TLV:

Tungsten                 5 mg/m3                                  5 mg/m3

Rhenium                 No exposure limit established     No exposure limit established

Engineering Controls: Ensure adequate ventilation to maintain exposures below occupational limits. Whenever possible the use of local exhaust ventilation or other engineering controls is the preferred method of controlling exposure to airborne dust and fume to meet established occupational exposure limits. Use good housekeeping and sanitation practices. Do not use tobacco or food in work area. Wash thoroughly before eating or smoking. Do not blow dust off clothing or skin with compressed air.

 

Respiratory Protection: If permissible levels are exceeded, use NIOSH approved dust respirator.

Eye Protection: Safety glasses

Skin Protection: Wear impermeable gloves, protective work clothing as necessary.

 

 

9   PHYSICAL AND CHEMICAL PROPERTIES

Appearance:

Form:                    Wire

Color:                    Silver gray metallic

Odor:                     Odorless

Odor Threshold:    Not determined

pH:                                             N/A

Melting Point:                            >3180 oC

Boiling Point:                             No data

Flash Point:                               N/A

Evaporation Rate:                     N/A

Flammability:                            No data

Upper Flammable Limit:            No data

Lower Flammable Limit:            No data

 

Vapor Pressure:                         No data

Vapor Density:                           N/A

Relative Density (Specific Gravity):     19.4 - 19.7 g/cc

 

Solubility in H2O:                         Insoluble

Partition Coefficient (n-octanol/water):   Not determined

 

Autoignition Temperature:         No data

Decomposition Temperature:     No data

Viscosity:                                     N/A

 

 

10   STABILITY AND REACTIVITY

Reactivity: No data

Chemical Stability: Stable under recommended storage conditions.

Possibility of Hazardous Reactions: No data

Conditions to Avoid: High temperatures in air.

Incompatible Materials: Strong oxidizers.

Hazardous Decomposition Products: Metal oxide fume.

 

 

11   TOXICOLOGICAL INFORMATION

Likely Routes of Exposure: Inhalation, skin, eyes. Product as shipped does not present an inhalation hazard; however subsequent operations may create dusts or fumes which could be inhaled.

Symptoms of Exposure: Fines/dusts may irritate skin and eyes.

 

Acute and Chronic Effects:

Tungsten: No data

Rhenium: No data

Acute Toxicity: No data

Carcinogenicity: No components of this alloy have been identified by NTP or IARC as carcinogenic.

To the best of our knowledge the chemical, physical and toxicological characteristics of the substance are not fully known.

 

 

12   ECOLOGICAL INFORMATION

Ecotoxicity: No data

Persistence and Degradability: No data

Bioaccumulative Potential: No data

Mobility in Soil: No data

Other Adverse Effects: No further relevant information available.

 

 

13   DISPOSAL CONSIDERATIONS

Waste Disposal Method:

Product: Dispose of in accordance with Federal, State and Local regulations.

Packaging: Dispose of in accordance with Federal, State and Local regulations.

 

 

14   TRANSPORT INFORMATION

Shipping Regulations: Not regulated

UN Number:                            N/A

UN Proper Shipping Name:    N/A

Transport Hazard Class:        N/A

Packing Group:                       N/A

Marine Pollutant:                    No

 

 

15   REGULATORY INFORMATION

TSCA Listed: All components are listed.

Regulation (EC) No 1272/2008 (CLP): N/A

Canada WHMIS Classification (CPR, SOR/88-66): N/A

HMIS Ratings: Health: 0     Flammability: 0     Reactivity: 0

NFPA Ratings: Health: 0     Flammability: 0      Reactivity: 0

Chemical Safety Assessment: A chemical safety assessment has not been carried out.

 

 

16   OTHER INFORMATION

The information contained in this document is based on the state of our knowledge at the time of publication and is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. ESPI Metals makes no representation, warranty, or guarantee of any kind with respect to the information contained in this document or any use of the product based on this information. ESPI Metals shall not be held liable for any damages resulting from handling or from contact with the above product. Users should satisfy themselves that they have all current data relevant to their particular use.

 

Prepared by:              ESPI Metals

Revised/Reviewed:   January 2015