Contact Us
| ESPI Metals 1050 Benson Way Ashland, Oregon 97520 541.488.8311 telephone 800.638.2581 toll-free 541.488.8313 fax 800.488.0060 toll-free fax sales@espimetals.com |
Precious Metal Prices
![]() |
Serving Research Institutions Worldwide Since 1950 |
|
MATERIAL SAFETY DATA SHEET
I. PRODUCT IDENTIFICATION Manufacturer/Supplier: ESPI Metals Toll Free (800) 638-2581 * Fax (541) 488-8313 E-Mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Product Name: Palladium Chloride
II. HAZARDOUS INGREDIENTS ACGIH/TLV (Units): None published
III. PHYSICAL DATA Boiling Point: Decomposes Melting Point: N/A Specific Gravity: N/A Solubility in H2O: Moderate to Insoluble Appearance and Odor: Brown-Red
IV. FIRE AND EXPLOSION HAZARDS DATA Flash Point (Method Used): N/A Autoignition Temperature: Non-Flammable Flammable Limits: Upper: N/A Lower: N/A Extinguishing Media: As applicable to surroundings Special Fire Fighting Procedures: Air mask Unusual Fire & Explosion: May emit toxic fumes of C12
V. HEALTH HAZARD INFORMATION Threshold Limit Value: None published Effects of Over Exposure: May cause eye, throat, skin irritation. An experimental carcinogen. EMERGENCY AND FIRST AID PROCEDURES: EYES: Flush with copious amounts of water for 15 minutes. SKIN: Wash with soap and water and a large volume of water. Seek medical assistance as necessary, especially if irritation develops or persists. INHALATION: Remove from exposure, seek immediate medical attention. INGESTION: Seek immediate medical attention.
VI. REACTIVITY DATA Stability: Stable Incompatibility (Material to Avoid): ZN, Mg, Al, HNO3, Acids, Alkalis, Organic solvents, Cyan. Hazardous Decomposition Products: PdO, C12 Hazardous Polymerization: Will not Occur
VII. SPILL OR LEAK PROCEDURES Steps to Be Taken in Case Material Is Released or Spilled: Place in a sealed container. Waste Disposal Method: In accordance with Local, State and Federal Waste Disposal Regulations. Ship to precious metal refiner.
VIII. SPECIAL PROTECTION INFORMATION Respiratory Protection (Specify Type): NIOSH/MSHA approved Ventilation: Local exhaust Protective Gloves: For all contact rubber Eye Protection: Safety goggles Other Protective Equipment:
IX. SPECIAL PRECAUTIONS Other Handling and Storage Conditions: Store in cool dry place. Keep tightly sealed when not in use. Wash thoroughly after handling. Do not get in eyes, on skin or clothing. Do not breathe dust, vapor, mist, or gas. Keep away from heat, sparks and open flames. Do not store near combustibles. Empty container may contain hazardous residues. Flammable solid.
The above information is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. ESPI shall not be held liable for any damage resulting from handling or from contact with the above product.
Prepared by: S. Dierks Dated: January 1994 |